• Energy
  • TECHnPower
  • Services
  • About us
En Es Gl
  • Energy generation
    • Wind Power
    • Hydroelectric
  • Energy storage
    • Storage
  • logo-enerxia

    We generate renewable energy as an independent power producer since 1992, with hydropower plants, wind farms and solar plants.

  • Applications
    • Energy Storage
    • Data Centers
    • Wind Power
    • Solar Power
    • PV hybridization-DC Coupling
    • Wind hybridization
  • Product families
    • Wind turbines
    • Storage converters
    • Photovoltaic inverters
    • Battery storage systems
  • logo-technpower

    We design and manufacture proprietary technology for power electronics, energy storage and wind power generation.

    Discover Norvento TECHnPower
  • Solutions
    • Decarbonization
    • Energy Engineering
    • EPC Energy
    • Operation & Maintenance
    • 24/7 Control Center
    • Monitoring & Control
  • logo-technpower

    We design and manufacture proprietary technology for power electronics, energy storage and wind power generation.

    Discover Norvento TECHnPower
  • Company
    • Get to know us better
    • Our team
    • Innovation
    • Sustainability
    • CIne, our Zero-Energy Building
    • neFO, our zero-emission manufacturing center at the European forefront
  • Work with us
    • Your career at Norvento
    • Talent Scholarship Scheme
  • Communication
    • Press room
    • Blog
    • Contact us
  • Norvento Enerxía

    We generate renewable energy as an independent power producer since 1992, with hydropower plants, wind farms and solar plants.

  • Norvento TECHnPower

    We design and manufacture proprietary technology for power electronics, energy storage and wind power generation.

    Discover Norvento TECHnPower

< Back | 30 October 2026

BLACKSTART

Restarting the system

Let’s consider a hydro plant with a full reservoir or a combined-cycle plant with gas waiting in the pipeline. They have all the primary energy they need, and yet neither can start up if it lacks the electricity required for activation, pumps, cooling, or control systems. When an electrical system drops to zero, that is the situation for almost all power plants: before they can generate power, they need to receive energy. Someone has to take the first step.

That first step is an autonomous startup, or black start: a facility’s ability to start up without an external power source and restore power to a portion of the grid that has lost power. It is only the beginning of the system’s restoration—a process that takes hours, during which the grid is rebuilt piece by piece without ever losing the balance between generation and demand.

Building a network from the beginning

Restoration proceeds in three stages. First, units capable of autonomous startup form small, stable electrical islands. Next, these islands expand by energizing lines and transformers until they reach other power plants, which can then power their auxiliary systems and join the process. Finally, with a robust grid in place, demand is gradually restored.

Restoration plans involve two approaches [1]. In the top-down strategy, power is supplied from a neighboring system via interconnections. In the bottom-up strategy, the system restores itself using its own resources, starting with local islands that grow and synchronize with one another. In practice, both approaches are combined.

Figure 1. Restoration strategies: one area is restored from a neighboring system (top-down), while several islands formed by self-starting power plants grow and merge with one another (bottom-up).

For decades, this role has fallen to a small group of technologies, led by hydro power plants: they have energy stored in the reservoir, modest auxiliary equipment, and the ability to take on load quickly. These technologies can start up autonomously, have sufficient energy reserve, and can control voltage and frequency when load blocks are connected. Furthermore, because of the role they play during a black start, these capabilities are tested periodically.

The shift in the generation mix changes this scenario. CIGRE notes that most of the power electronics-connected resources installed to date cannot be replaced and warns that retrofitting them is much more expensive—if it is even possible [2]. The decommissioning of conventional power plants reduces the number of options available for restoring power to the grid.

Learning from the April 28 rerun

Beyond the causes of the blackout on April 28, 2025, the restoration of the Iberian power system offers a valuable lesson. At 12:33 p.m., restoration plans were activated in the seven zones into which the peninsular system is organized, each with at least two hydro plants capable of autonomous startup [3]. Ten minutes later, power began arriving from France, and shortly thereafter, from Morocco. By approximately 4:00 a.m. the following day, the entire transmission grid was energized, and by 7:00 a.m., 99.95% of demand had been restored [3][4].

Figure 2. Demand response in the Spanish peninsular system between April 28 and 29, 2025, and key milestones in the restoration process. Prepared by the author based on [3] and [4].

The ENTSO-E final report offers a lesser-known insight. Of the twelve hydro black starts carried out in Spain, more than half experienced trips or the island could not be sustained, and several of those areas ended up being energized from areas that had already been restored. [3]. Among the causes identified in the report are difficulties in controlling power and frequency when multiple generators share an island, synchronization problems, protection settings, a lack of capacity to absorb reactive power, and failures when closing high-voltage circuit breakers.

There was no shortage of startup resources. The challenge was to create stable clusters, maintain them, and scale them under real-world conditions. That is why the report recommends conducting real-world, periodic tests, beyond simply testing each unit individually.

That lesson has already been incorporated into the regulations. In Spain, Operating Procedure 7.6 classifies autonomous startup as a paid service and provides for its extension, in a second phase, to any technology capable of demonstrating this capability, including energy storage [5].

The physics of powering a grid from zero

Every switch that closes during a reset puts the existing island to the test. The first obstacle is usually a transformer. When it is connected, the magnetic flux in its core does not immediately reach steady-state conditions: depending on the instant in the voltage waveform at which the switch closes, an additional component appears that, in the worst-case scenario, can double the flux. Since the core is designed to operate near its saturation limit, this excess causes it to saturate, and the transformer draws a magnetizing current—or inrush current—for a few instants that is several times its rated current; this current takes tens or hundreds of milliseconds to decay. If the core retains residual magnetism from the last disconnection and this adds in the same direction, the peak is even greater (Figure 3).

Figure 3. Magnetizing current of a transformer under no-load conditions when it is suddenly energized, at the most unfavorable instant and with residual magnetism. Illustrative simulation of a single-phase transformer; values are expressed as a fraction of the rated current.

In practice, the replacement combines two approaches. If the transformer is connected before the power source forming the island starts up, the voltage can ramp up from zero: the flux increases gradually, the core does not become saturated, and the inrush current is virtually eliminated. If the circuit must be closed on a de-energized transformer with the island already formed, the inrush current is unavoidable, and the unit forming the island must be capable of supplying it without losing control of the voltage—one of the key requirements for any autonomous blackstart resource. Some substations also use synchronized switching devices, which select the closing instant based on residual magnetism, although their use is far from widespread [6].

On the other hand, long transmission lines—and especially cables—present the opposite problem. When unloaded, they behave like a capacitor: they draw a capacitive current and raise the voltage at their end. When connected, an oscillation also occurs between the cable’s capacitance and the source’s inductance, which can cause the voltage to rise to nearly twice its nominal value for a few milliseconds. The weaker the source, the greater the overvoltage that remains once the transient has subsided, and an island in the process of being re-energized is, by definition, a weak source (Figure 4). Whoever forms the island must absorb that reactive power to keep the voltage within its limits, which is why autonomous blackstart requirements explicitly call for controlling the voltage using all available reactive capacity [5].

Figure 4. Energization of an empty cable from a strong grid and from a weak island. Illustrative simulation using a lumped-parameter model; values are in units of the nominal voltage.

Next comes the demand, which also does not behave as it did before the blackout. After a prolonged outage, refrigerators, pumps, air conditioning systems, and industrial processes all attempt to start up at once, causing consumption to spike well above normal levels for several minutes. That is why the loads are restored in stages, sized so that an island—even a small one—can absorb them. The Spanish procedure, for example, requires that each autonomous blackstart unit accommodate steps of at least 5% of its rated power [5].

Protection devices add another layer of protection. Their settings are calculated for a robust, established grid with high short-circuit currents. On a small island—and even more so if it is powered by converters—they may fail to detect an actual fault or mistake a connection current for a short circuit. And when two islands are ready to be connected, their voltages, frequencies, and phase angles must match within narrow margins.

Until now, these phenomena have been studied with synchronous generators in mind. The incorporation of resources connected via converters requires a reevaluation of how they are handled, because their response during these maneuvers depends on their control and current limits.

New key players: storage, renewables, and HVDC

In a blackout, there is no reference voltage to follow, so only a grid-forming converter can initiate an island operation. This is a necessary but not sufficient condition: the auxiliary systems, cooling, communications, control systems, and the power source itself must all operate off-grid. Black start is a capability of the entire facility.

Field tests have been accumulating. In 2017, California’s Imperial Irrigation District used a 33 MW battery to start up a 44 MW gas turbine [7]. In 2020, the Dersalloch wind farm in Scotland, equipped with grid-forming control, formed an island and energized part of the distribution grid [8]. In 2023, as part of the British Distributed ReStart project, an 11.6 MVA battery single-handedly energized sections of the distribution and transmission grids, including transformers [9]. HVDC links with voltage-source converters can also energize a grid from a neighboring system, provided that the other end is in service [10].

Battery storage systems must be sized based on several parameters: the power the batteries are capable of delivering; the energy—or how long they can deliver a given power level; and the minimum energy reserve required to provide a backup service.

Powering grids with energy storage: The Norvento TECHnPower experience

The phenomena described above encounter a very specific limitation in the converter: current. A synchronous generator can deliver several times its rated current for a few moments; the semiconductors in a converter cannot. Short-circuiting a de-energized transformer or connecting a cold load are precisely the situations in which this difference becomes apparent, which is why a converter’s self-starting capability depends as much on how it manages current during transients as on its rated power.

At Norvento TECHnPower, the nGM storage converters were designed from the outset as grid-forming devices, and the nBESS systems that incorporate them have been tested for autonomous startup: they generate voltage in a non-energized grid, energize transformers and loads, operate in coordination with other units, and serve as a reference for synchronizing other resources. When a circuit breaker is closed on an unenergized transformer, the converter limits the current within a few milliseconds to a configurable level—several times its rated current—without ceasing to generate voltage or affecting its ability to operate in parallel, and the voltage recovers as the transformer becomes magnetized (Figure 5). For the most demanding applications, the equipment can supply a current of up to 3.5 times the rated current for hundreds of milliseconds (Figure 6).

Figure 5. Successive energizations of a de-energized transformer from nGM converters that make up the grid. On the left, the complete sequence; on the right, a close-up of a switching operation: the current is limited within milliseconds to a configurable level, and the voltage recovers as the transformer becomes magnetized. Actual measurement; values are per unit of the converter’s nominal voltage and current.
Figure 6. Extended overcurrent capacity of the nGM: When faced with a deep voltage dip, the converter maintains a current several times the rated value for hundreds of milliseconds and continues to supply power to the fault until it clears. Actual measurement on nGM equipment; values in per-unit.

Its modular architecture allows for thinking on a larger scale. Each unit provides its own power and current capacity, so that the power supply capacity grows with the number of converters and the power output of each one. As storage systems grow, the line between powering a microgrid and participating in the first phases of a replacement plan shifts.

A network ready to make a comeback

Autonomous startup raises the question of stability in its most demanding form: what happens when there is nothing left to rely on and the network must be rebuilt from the beggining.

Grid-forming converters, energy storage, and HVDC interconnections expand the options, and regulators are beginning to recognize this. Their contribution will be all the more robust the better they are integrated into coordinated replacement plans and the more their performance is tested. The energy transition is often measured by the amount of energy we are capable of producing; it is also worth measuring it by how quickly and reliably we restore power when the grid fails.

References

[1] Commission Regulation (EU) 2017/2196 of November 24, 2017, establishing a network code on emergency and restoration of the power system. OJEU L 312, Nov. 28, 2017.

[2] CIGRE (2023). Technical Brochure 911, Power System Restoration Accounting for a Rapidly Changing Power System and Generation Mix. WG C2.26.

[3] ENTSO-E (2026). Final Report on the Grid Incident in Spain and Portugal on April 28, 2025. Expert Panel, March 20, 2026.

[4] Red Eléctrica (2025). Red Eléctrica’s response to the incident of April 28. Press release, April 28, 2025, updated May 1, 2025.

[5] CNMC Resolution of June 19, 2026, approving Operating Procedure 7.6, “Autonomous ce.” Official State Gazette (BOE) No. 156, June 27, 2026.

[6] Brunke, J. H.; Fröhlich, K. J. (2001). Elimination of transformer inrush currents by controlled switching. Part I: Theoretical considerations. IEEE Transactions on Power Delivery, 16(2), 276–280.

[7] Utility Dive (2017). California municipal IID completes first U.S. demonstration of black start battery.

[8] ScottishPower Renewables (2020). Dersalloch wind farm black start demonstration.

[9] NESO, SP Energy Networks, TNEI (2023). Distributed ReStart: Final Findings and Proposals for Electricity System Restoration from DERs.

[10] CIGRE (2026). Technical Brochure 981, Application of VSC HVDC in a System Black Start Restoration. WG B4.94.

Sources consulted on October 14, 2026.

Daniel Calvo Guillén

Daniel Calvo Guillén holds a bachelor’s and master’s degree in Electronic Engineering from the University of Alcalá. Throughout his career, he has worked in sectors as diverse as telecommunications, industrial electronics, and, currently, renewable energy.

He began his professional career at Indra. Later, at Norvento, he built on his experience as an electronic design engineer before joining Fibernet, where he developed his expertise as an engineer specializing in FPGA design and development. In 2023, he rejoined the Power Electronics R&D team at Norvento TECHnPower, where he works on the development of FPGAs and embedded software for power electronics.

Share: Facebook Mail Linkedin Twitter
< The Rules Governing the Grid – II  
  • Energy
    • Energy generation
      • Wind Power
      • Hydroelectric
    • Energy storage
      • Storage
  • TECHnPower
    • Applications
      • Energy Storage
      • Data Centers
      • Wind Power
      • Solar Power
      • PV hybridization-DC Coupling
      • Wind hybridization
    • Product families
      • Wind turbines
      • Storage converters
      • Photovoltaic inverters
      • Battery storage systems
  • Services
    • Solutions
      • Decarbonization
      • Energy Engineering
      • EPC Energy
      • Operation & Maintenance
      • 24/7 Control Center
      • Monitoring & Control
  • About us
    • Company
      • Get to know us better
      • Our team
      • Innovation
      • Sustainability
      • CIne, our Zero-Energy Building
      • neFO, our zero-emission manufacturing center at the European forefront
    • Work with us
      • Your career at Norvento
      • Talent Scholarship Scheme
    • Communication
      • Press room
      • Blog
      • Contact us
  • Linkedin
  • X
  • Facebook
  • Instagram
  • © 2026
  • R&D Projects
  • Legal notice
  • Privacy policy
  • Cookie policy
  • Whistleblower Channel
En
  • Es
  • Gl
  • Energy
  • TECHnPower
  • Services
  • About us
  • Linkedin
  • X
  • Facebook
  • Instagram
Energy
  • Energy generation
    • Wind Power
    • Hydroelectric
  • Energy storage
    • Storage
  • logo-enerxia

    We generate renewable energy as an independent power producer since 1992, with hydropower plants, wind farms and solar plants.

TECHnPower
  • Applications
    • Energy Storage
    • Data Centers
    • Wind Power
    • Solar Power
    • PV hybridization-DC Coupling
    • Wind hybridization
  • Product families
    • Wind turbines
    • Storage converters
    • Photovoltaic inverters
    • Battery storage systems
  • logo-technpower

    We design and manufacture proprietary technology for power electronics, energy storage and wind power generation.

    Discover Norvento TECHnPower
Services
  • Solutions
    • Decarbonization
    • Energy Engineering
    • EPC Energy
    • Operation & Maintenance
    • 24/7 Control Center
    • Monitoring & Control
  • logo-technpower

    We design and manufacture proprietary technology for power electronics, energy storage and wind power generation.

    Discover Norvento TECHnPower
About us
  • Company
    • Get to know us better
    • Our team
    • Innovation
    • Sustainability
    • CIne, our Zero-Energy Building
    • neFO, our zero-emission manufacturing center at the European forefront
  • Work with us
    • Your career at Norvento
    • Talent Scholarship Scheme
  • Communication
    • Press room
    • Blog
    • Contact us
  • Norvento Enerxía

    We generate renewable energy as an independent power producer since 1992, with hydropower plants, wind farms and solar plants.

  • Norvento TECHnPower

    We design and manufacture proprietary technology for power electronics, energy storage and wind power generation.

    Discover Norvento TECHnPower
Gestionar consentimiento

At Norvento Enerxía we use our own and third-party cookies for different purposes: performance, security and analytics. You can customize your preferences through the configuration panel, as well as obtain additional information about the processing of your data, including the exercise of your rights, by consulting our Cookies Policy.
You can change the settings at any time by returning to the dashboard, clicking on a different option, and refreshing the web page. 

Technicals Always active
Analítica
Preferencias
El almacenamiento o acceso técnico es necesario para la finalidad legítima de almacenar preferencias no solicitadas por el abonado o usuario.
Statistics
El almacenamiento o acceso técnico que es utilizado exclusivamente con fines estadísticos. El almacenamiento o acceso técnico que se utiliza exclusivamente con fines estadísticos anónimos. Sin un requerimiento, el cumplimiento voluntario por parte de tu proveedor de servicios de Internet, o los registros adicionales de un tercero, la información almacenada o recuperada sólo para este propósito no se puede utilizar para identificarte.
Marketing
El almacenamiento o acceso técnico es necesario para crear perfiles de usuario para enviar publicidad, o para rastrear al usuario en una web o en varias web con fines de marketing similares.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
Set my preferences
  • {title}
  • {title}
  • {title}