• Energy
  • TECHnPower
  • Services
  • About us
En Es Gl
  • Energy generation
    • Wind Power
    • Hydroelectric
  • Energy storage
    • Storage
  • logo-enerxia

    We generate renewable energy as an independent power producer since 1992, with hydropower plants, wind farms and solar plants.

  • Applications
    • Energy Storage
    • Data Centers
    • Wind Power
    • Solar Power
    • PV hybridization-DC Coupling
    • Wind hybridization
  • Product families
    • Wind turbines
    • Storage converters
    • Photovoltaic inverters
    • Battery storage systems
  • logo-technpower

    We design and manufacture proprietary technology for power electronics, energy storage and wind power generation.

    Discover Norvento TECHnPower
  • Solutions
    • Decarbonization
    • Energy Engineering
    • EPC Energy
    • Operation & Maintenance
    • 24/7 Control Center
    • Monitoring & Control
  • logo-technpower

    We design and manufacture proprietary technology for power electronics, energy storage and wind power generation.

    Discover Norvento TECHnPower
  • Company
    • Get to know us better
    • Our team
    • Innovation
    • Sustainability
    • CIne, our Zero-Energy Building
    • neFO, our zero-emission manufacturing center at the European forefront
  • Work with us
    • Your career at Norvento
    • Talent Scholarship Scheme
  • Communication
    • Press room
    • Blog
    • Contact us
  • Norvento Enerxía

    We generate renewable energy as an independent power producer since 1992, with hydropower plants, wind farms and solar plants.

  • Norvento TECHnPower

    We design and manufacture proprietary technology for power electronics, energy storage and wind power generation.

    Discover Norvento TECHnPower

< Back | 14 October 2026

The Rules Governing the Grid – II

Grid Following

Grid Following: The Control Mechanism Behind Grid-Connected Renewable Energy Generation

For decades, much of the electricity generation came from large synchronous machines that, by their very physical nature, helped determine the grid’s key variables. The growing presence of photovoltaic and wind power generation, as well as energy storage, is changing this landscape. Many of these resources are connected to the grid via electronic power converters. With power electronics, the behavior of the system depends largely on the control algorithm: how it synchronizes, how it exchanges power, and how it responds to disturbances.

Among the most commonly used strategies for integrating these resources, Grid Following Control (GFL) stands out. But what does it mean for a converter to “follow” the grid, and what happens when that grid is no longer a sufficiently strong reference?

1. What does it mean to follow the network?

The Grid Following philosophy is based on a simple idea: the voltage and frequency are already set, and the converter synchronizes with them to exchange the desired power. From the grid’s perspective, a GFL can be understood, in simplified terms, as a controlled current source: it measures the voltage at the connection point and calculates the currents needed to meet its setpoints. This philosophy works particularly well when the grid is sufficiently robust and the converter’s actions have little effect on the voltage at the connection point. The converter, therefore, first identifies the electrical state of the grid and then decides how to act upon it.

The conceptual difference from Grid Forming (GFM) is clear: a GFL uses grid voltage as a reference for synchronization, while a GFM establishes its own voltage and frequency reference. This does not make the GFL a passive element. Current controls can regulate active and reactive power, contribute to voltage and frequency support, and respond during disturbances.

2. The PLL: Finding a Reference Online

To control the currents exchanged with a three-phase grid, the converter must know its position relative to the grid voltage at all times. One of the most commonly used solutions is the Phase-Locked Loop (PLL), which estimates the electrical angle of the measured voltage and, based on its variation, also allows the frequency to be determined.

However, knowing the angle is not the ultimate goal. In a three-phase network, voltages and currents are sinusoidal signals that are out of phase with one another, so their instantaneous values change continuously even when the system is in steady state. Working directly with these signals makes it difficult to design controllers, since the variables to be controlled are, by nature, oscillating.

Coordinate transformations are used to simplify the problem. One of the most common is the Park transformation, which uses the angle θ provided by the PLL to transform the three-phase magnitudes abc into a rotating reference frame dq that rotates in sync with the line voltage. 

The concept can be easily visualized: while we observe three sinusoidal signals from a stationary reference frame, when we move to a frame rotating at the same speed as the voltage vector, that vector appears to be practically stationary. Therefore, under balanced, sinusoidal three-phase conditions, the fundamental quantities are represented by approximately constant values d y q.

This makes control considerably easier. If the d-axis is aligned with the line voltage vector, vq ≈ 0 is typically obtained, and the components id and iq can be associated, under these conditions and according to the convention used, with the control of active and reactive power. In this way, the problem of regulating three-phase sinusoidal signals is transformed into that of regulating practically constant quantities through control loops. 

The entire operation can therefore be understood as a chain: 

Mains voltage → PLL → electrical angle → dq transformation → current references → current control → converter

The PLL is not just a measurement block: it is part of the control dynamics. This is important because the voltage it uses as a reference can also be affected by the current injected by the converter itself.

3. From a power rating to an injected current

Once synchronized, the converter must transform the power setpoints into current setpoints. These setpoints may come from a plant controller, an energy management system, or higher levels of control. The external loops generate the current setpoints, and the internal loops—which are faster—act on the synthesized voltage so that the actual currents follow them.

This is how a hierarchical structure is formed: power, voltage, or power factor controls generate reference signals, while current loops directly govern the converter’s electrical response. Power electronics enable a very fast response, although this is always limited by the hardware, filters, power source, and control design.

4. Much more than simply injecting active power 

In addition to monitoring active and reactive power, a modern GFL can incorporate grid support functions. For example, it can adjust reactive power to help regulate voltage through Q-V control. It can also vary active power in response to frequency deviations through P-f control.

Grid codes may also require that the system remain connected during certain disturbances and provide reactive power to help restore voltage. This is where features such as Fault Ride Through (FRT), dynamic voltage support, and Fast Frequency Response (FFR) come into play. Grid-Following does not, therefore, mean a lack of grid support. The question is how these functions behave when electrical conditions change.

5. What happens when the grid is no longer strong?

No real grid is an ideal voltage source. There is an equivalent impedance between the converter and the grid, so any variation in the injected current also produces a voltage variation at the connection point. 

The grid impedance can be understood, in simplified terms, as a gain between current and voltage variations:

ΔV ≈ Zred ΔI

Therefore, when faced with the same current change—for example, caused by a reactive power step—a strong network with low impedance will experience only a small voltage variation. In a weak network with higher impedance, that same step will produce a much larger voltage variation.

This increased sensitivity is particularly important in a GFL, since the PCC voltage also serves as the reference used by the PLL for synchronization. As the grid impedance increases, the converter’s own operations have a greater impact on its synchronization reference, increasing the coupling between the grid and the control system and potentially reducing stability margins.

This concept is directly related to network strength, which can be characterized by metrics such as the Short Circuit Ratio (SCR). Generally speaking, a high SCR corresponds to a strong network, while a low SCR indicates a weaker network and greater voltage sensitivity to the converter’s operations.

6. When many converters are connected to the same network

As the number of connected converters increases, so does the coupling between their controls and the grid. Each unit no longer behaves completely independently: a variation caused by one converter can alter the electrical conditions observed by the others and trigger their respective controls. 

These interactions can lead to oscillations or stability issues that do not become apparent when each piece of equipment is studied in isolation. Furthermore, the variety of manufacturers, control strategies, and simulation tools adds to the complexity of the analysis.

For this reason, systems with a high degree of converter integration require sufficiently detailed, validated, and highly standardized models capable of accurately representing the dynamic interactions between the various components.

These dynamics make it necessary to analyze stability at the system level, rather than just the individual behavior of each converter.

7. From RMS Models to EMT Studies

Simulation is essential for studying these interactions, but there is no single model suitable for all phenomena. RMS models are appropriate for relatively slow dynamics and allow for the study of large systems at a reasonable computational cost. When rapid control dynamics, PLLs, current limiters, or electromagnetic transients are of interest, it may be necessary to use EMT models.

The choice therefore depends on the phenomenon to be analyzed. Impedance analysis offers another perspective: it characterizes the dynamic relationship between the converter’s voltage and current and compares it to the grid impedance. The central idea is simple: stability depends on the interaction between the converter and the grid.

8. The limitation no algorithm can overcome: current

There is a physical limit that no control system can exceed: the converter’s maximum allowable current. During a severe disturbance, current setpoints may exceed this limit, requiring a limiting strategy to keep the equipment within its safe operating conditions.

During a fault, the converter must remain synchronized, operate within its physical limits, and meet the requirements established by the grid code. The problem arises when the available current does not allow all required performance criteria to be met simultaneously, particularly the reactive power injection requirements. Under these conditions, the limitation strategy determines how the available capacity is allocated and which variables are prioritized.

This problem affects both Grid following and Grid Forming converters, although the limiting strategies and their effects on control differ. Therefore, their behavior during faults must be analyzed by taking into account grid requirements, the control strategy, and the physical limits of the equipment.

Analyzing the response during a disturbance therefore requires considering what happens when the converter enters saturation. That is where the difference arises between what the algorithm requests and what the equipment can physically deliver.

9. So, why do we need Grid Forming?

The shift toward Grid Forming does not mean replacing Grid Following. Both strategies offer different advantages. GFL converters are particularly effective at controlling the exchange of active and reactive power by taking advantage of the current loops in the dq frame, and they are a highly suitable solution for integrating renewable generation.

Furthermore, technologies such as solar and wind power depend on the instantaneous availability of their primary resource, which limits their ability to serve as a robust power reference for the grid. In contrast, GFM converters stand out for their ability to establish and maintain voltage and frequency, helping to keep the grid robust when synchronous generation declines.

Therefore, the future does not necessarily involve choosing between GFL and GFM, but rather combining both strategies by leveraging the strengths of each and coordinating them appropriately within the electric system.

Conclusion

Grid Following remains a fundamental architecture for the integration of power electronics-based resources, especially when the energy source is renewable and precise control of active and reactive power is required. Its control structure allows for rapid and precise regulation of power exchange with the grid.

Its main challenges arise when the grid ceases to provide a sufficiently robust reference. In this scenario, grid-forming capabilities—which establish and maintain voltage and frequency—become particularly important.

Therefore, GFL and GFM should not be viewed as mutually exclusive strategies, but rather as complementary ones that depend on the needs of the system and the connected energy resource. The challenge lies in coordinating both approaches, leveraging GFL’s precision in power control and GFM’s ability to contribute to a robust and stable grid.

Daniel Cueli Valdés

Daniel Cueli Valdés holds a degree in Industrial Electronics and Automation Engineering and a master’s degree in Electrical Energy Conversion and Power Systems from the University of Oviedo. His professional work focuses on power electronics, converter control and the integration of energy storage systems into electrical grids.

His work focuses on the modeling, simulation and validation of converters using RMS and EMT models, as well as on the development and implementation of control strategies in PLCs.

Share: Facebook Mail Linkedin Twitter
< The Rules Governing the Grid – I BLACKSTART >
  • Energy
    • Energy generation
      • Wind Power
      • Hydroelectric
    • Energy storage
      • Storage
  • TECHnPower
    • Applications
      • Energy Storage
      • Data Centers
      • Wind Power
      • Solar Power
      • PV hybridization-DC Coupling
      • Wind hybridization
    • Product families
      • Wind turbines
      • Storage converters
      • Photovoltaic inverters
      • Battery storage systems
  • Services
    • Solutions
      • Decarbonization
      • Energy Engineering
      • EPC Energy
      • Operation & Maintenance
      • 24/7 Control Center
      • Monitoring & Control
  • About us
    • Company
      • Get to know us better
      • Our team
      • Innovation
      • Sustainability
      • CIne, our Zero-Energy Building
      • neFO, our zero-emission manufacturing center at the European forefront
    • Work with us
      • Your career at Norvento
      • Talent Scholarship Scheme
    • Communication
      • Press room
      • Blog
      • Contact us
  • Linkedin
  • X
  • Facebook
  • Instagram
  • © 2026
  • R&D Projects
  • Legal notice
  • Privacy policy
  • Cookie policy
  • Whistleblower Channel
En
  • Es
  • Gl
  • Energy
  • TECHnPower
  • Services
  • About us
  • Linkedin
  • X
  • Facebook
  • Instagram
Energy
  • Energy generation
    • Wind Power
    • Hydroelectric
  • Energy storage
    • Storage
  • logo-enerxia

    We generate renewable energy as an independent power producer since 1992, with hydropower plants, wind farms and solar plants.

TECHnPower
  • Applications
    • Energy Storage
    • Data Centers
    • Wind Power
    • Solar Power
    • PV hybridization-DC Coupling
    • Wind hybridization
  • Product families
    • Wind turbines
    • Storage converters
    • Photovoltaic inverters
    • Battery storage systems
  • logo-technpower

    We design and manufacture proprietary technology for power electronics, energy storage and wind power generation.

    Discover Norvento TECHnPower
Services
  • Solutions
    • Decarbonization
    • Energy Engineering
    • EPC Energy
    • Operation & Maintenance
    • 24/7 Control Center
    • Monitoring & Control
  • logo-technpower

    We design and manufacture proprietary technology for power electronics, energy storage and wind power generation.

    Discover Norvento TECHnPower
About us
  • Company
    • Get to know us better
    • Our team
    • Innovation
    • Sustainability
    • CIne, our Zero-Energy Building
    • neFO, our zero-emission manufacturing center at the European forefront
  • Work with us
    • Your career at Norvento
    • Talent Scholarship Scheme
  • Communication
    • Press room
    • Blog
    • Contact us
  • Norvento Enerxía

    We generate renewable energy as an independent power producer since 1992, with hydropower plants, wind farms and solar plants.

  • Norvento TECHnPower

    We design and manufacture proprietary technology for power electronics, energy storage and wind power generation.

    Discover Norvento TECHnPower
Gestionar consentimiento

At Norvento Enerxía we use our own and third-party cookies for different purposes: performance, security and analytics. You can customize your preferences through the configuration panel, as well as obtain additional information about the processing of your data, including the exercise of your rights, by consulting our Cookies Policy.
You can change the settings at any time by returning to the dashboard, clicking on a different option, and refreshing the web page. 

Technicals Always active
Analítica
Preferencias
El almacenamiento o acceso técnico es necesario para la finalidad legítima de almacenar preferencias no solicitadas por el abonado o usuario.
Statistics
El almacenamiento o acceso técnico que es utilizado exclusivamente con fines estadísticos. El almacenamiento o acceso técnico que se utiliza exclusivamente con fines estadísticos anónimos. Sin un requerimiento, el cumplimiento voluntario por parte de tu proveedor de servicios de Internet, o los registros adicionales de un tercero, la información almacenada o recuperada sólo para este propósito no se puede utilizar para identificarte.
Marketing
El almacenamiento o acceso técnico es necesario para crear perfiles de usuario para enviar publicidad, o para rastrear al usuario en una web o en varias web con fines de marketing similares.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
Set my preferences
  • {title}
  • {title}
  • {title}